Create The Observer XT settings

Aim

To enable communication between The Observer XT and N-Linx Server.

Prerequisites

Procedure

  1. In The Observer XT, choose File > Preferences > N-Linx Settings.
  2. Select Use N-Linx server to connect with other applications.image.png
  3. In the N-Linx Server address field, enter the computer name of the computer with N-Linx server. If The Observer XT is installed on the same computer as N-Linx Server, leave the default entry Localhost.
  4. In the N-Linx Server port field, leave the default port 5672. Ask your system administrator for assistance if this port is used by another program.
  5. Click Test connection. If connection with N-Linx Server is found, the Status will change to Connected.
  6. Click OK.
  7. Choose Setup > Project Setup.
  8. Under Observation source, select Live Observation. The Devices window now opens. If not, click the Devices button.image.png
  9. Select MediaRecorder [Version number][Computer name] and click Edit Settings. MediaRecorder now opens if it is not already open.
    image.png
  10. Click Edit Settings again. A window with the available configurations (see Save the camera settings in Record video) now opens. Select the configuration file you want to use and click OK. If you do not select a configuration, Current Settings.mrs will be used.
    Optionally enter a unique name in the Identify device as field. This way you can control multiple instances of MediaRecorder with one instance of The Observer XT.
    image.png
  11. Repeat the steps 9 and 10 for each MediaRecorder instance.

Note

When you close MediaRecorder, the MediaRecorder line in the Devices window (step 9) will be grayed out and the status will change to Disabled. MediaRecorder will start when you create an observation.


Revision #9
Created 29 November 2023 23:20:56
Updated 20 December 2023 13:47:09